Jiangsu Hengxin Technology Co., Ltd.
Main products:Flexible Cable,Leaky Cable,Super Flexible RF Cable,Jumper Cable,Connectors
Products
Contact Us
  • Contact Person : Ms. Jin huiyi
  • Company Name : Jiangsu Hengxin Technology Co., Ltd.
  • Tel : 0086-510-87499573
  • Fax : 0086-510-87491427
  • Address : Jiangsu,Yixing,No.138,TaoDu Road,Dingshu Town,Yixing City
  • Country/Region : China
  • Zip : 214222

RG141-High temperature cable

RG141-High temperature cable
Product Detailed
heat resistance, fire resistance, flexible, moisture resistance, corrosion resistance, fine, easy soldering

Application: applied in 3G mobile communications network construction, antenna, communications equipment, supercomputers, and also used as signal transmission line in mobile phones, laptops and medical equipment, etc.

Construction Specifications

Item                                                   Material                                          Diameter (mm)

1. Inner Conductor            Silver Plated Copper Clad Steel                      0.94

2. Dielectric                                        PTFE                                                      2.95

3. Outer Conductor              Silver Plated Copper Braid                             3.45

4. Jacket                               Fiber Glass Braid or FEP                                 4.83

Electrical Specifications

  Capacitance (pF/m)                                                                      96

  Impedance (ohm)                                                                          50

  Velocity (%)                                                                                      70

  Maximum Operating Voltage (KV)                                             1.90

  Maximum Work Frequency (MHz)                                             8000

Mechanical Specifications

  Minimum Bending Radius (mm)                                                25

  Operation Temperature (°C)                                              -55~+200

Attenuation (20°C, Sea Level)

Frequency (GHz)              Attenuation (dB/m)               

            0.1                            0.13                         

            0.4                            0.26                        

            1.0                            0.42                         

            3.0                            0.78                         

            5.0                            1.05                         

 Note: Maximum attenuation value should be 110% of the nominal attenuation value.

RG141-High temperature cable



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.